PCB-8161-011A
    zoom_out_map

      PCB-8161-011A

      DIN rail mount strain gage signal conditioner, +/- 10 V & 4 to 20 mA outputs, calibrated in voltage, 10 VDC bridge excitation voltage, switch activated shunt, 12 to 28 VDC operation

        Specification Notes


        [1] Jumper selectable.
        [2] At full sensor load.

        English:SI:
        Performance
        Frequency Range1000 Hz1000 Hz
        Non-Linearity±0.01 % FS±0.01 % FS
        Zero Adjust Range(Output 1) (course)±60 %±60 %
        Zero Adjust Range (fine)±10 %±10 %
        Span Adjust Range(Output 1) (course)±0.05 to 5 mV/V±0.05 to 5 mV/V
        Span Adjust Range (fine)±20 %±20 %
        20 mA Adjust Range(Output 2.)±20 %±20 %
        4 mA Adjust Range(Output 2)±10 %±10 %
        Environmental
        Temperature Range+32 to +158 °F0 to +70 °C
        Electrical
        Excitation (Max Current)30 mA30 mA
        Excitation Voltage (±.05 %) (Sensor)10 VDC10 VDC [1]
        Output 1 (Voltage)±10 VDC±10 VDC [1]
        Output 2 (Current)4 to 20 mA4 to 20 mA
        Power Required (Current)60 mA60 mA [2]
        Power Required (Voltage)12 to 28 Vdc12 to 28 Vdc
        Physical
        Size - Height3.35 in89 mm
        Size - Width0.69 in18 mm
        Mounting35 mm DIN Rail35 mm DIN Rail
        Size - Length2.27 in58 mm

        * All specifications are at room temperature unless otherwise specified.

        PCB-8161-011A

        Specific References

        Download

        8161-011a_specs.pdf

        PCB-8161-011A_specs

        Download (1.15M)

        8161-011a_manual.pdf

        PCB-8161-011A_manual

        Download (1.15M)

        23570-c_drawings.pdf

        PCB-8161-011A_drawings

        Download (46.95k)